AFJ 2000

The AFJ 2000 extraction device already contains 3 filters, where  two filters are the main ones and a HEPA filter is used to complete
the air purification process. All the filters have a manometer  that shows clogging and filter status. The AFJ 2000 can extract  multiple machines at the same time.

THE PRINCIPLE OF AFJ

The polluted air enters the device through openings on the right or left side (1) and passes through the first main filter (2), where 85% of the particles are separated. The air then passes through another main filter (3), where 95% of the contaminated air is separated. Finally, the almost completely purified air passes through the HEPA filter, where we achieve an efficiency of 99.99%. This ensures that the device can be set up and installed inside a production hall or directly next to the machine to which the extraction device is connected. The extraction device is switched on and off with a switch located on the right side of the device (4). The oil that has been separated is collected in an oil sump (7), and a drain valve for draining the oil is located on the right side.